15m White 2835 LED Strip Roll for Layout Planning
SR005-120P2835IP20-15M
- Voltage
- 24V
- PCB width
- 10 mm
- Protection
- IP20

BEXLIGHTING / APPLICATION DESIGN NOTE
In a glass display, the source may be seen directly, reflected in a shelf, or repeated in the door glass. Compare shielded front, side and top positions against those three views. Shelf adjustment and cable movement need a separate detail from the lighting effect.
External reference photograph; CCT not documented. Not a BEXLIGHTING project. Photo: Lewis Westwood Flood · Unsplash License. Resized and compressed.
Begin with the merchandise height, shelf spacing and shopper eye positions. A top-only source can leave lower shelves in shadow; a light on each shelf introduces more wiring and more possible reflections. Neither arrangement should be chosen from an empty frontal photograph.
| Position to investigate | Potential purpose | Detail to resolve |
|---|---|---|
| Shielded front edge | Direct light back towards the goods | Source concealment and front-glass reflection |
| Vertical side frame | Serve several shelf levels from the frame | Shadows from shelf brackets and merchandise |
| Top of the case | Simpler fixed source location | Light reaching lower levels with stock in place |
These are candidate arrangements, not claims of measured performance. Put a tall and a low item on adjacent shelves and review both straight-on and obliquely.
A fixed cable exit may work at one shelf height and become strained or visible at another. Show the permitted shelf positions, connection access and slack-management method. Keep cables out of door seals, shelf supports and sharp edges. The manufacturer-approved connection detail must suit the actual movement.
For illustration, four illuminated shelves each needing a 700 mm strip describe four sections and 2.8 m of strip. That quantity says nothing about a safe single run or suitable connector; the reviewed circuit and equipment limits determine those.
Use the 4000K vs 5000K article when those are the intended choices. For warm wood or decorative objects, a different pair may be relevant. CCT does not establish colour fidelity, and glass reflections are not corrected by changing only the Kelvin value.
Send a cabinet elevation, shelf depth and spacing, merchandise examples, shopper sightlines, adjustable/fixed shelf decision and accessible service side. Identify which parts are to be supplied as finished modules. Product candidates should be connected to these requirements, not presented as universally approved for glass cases.
This is an application design note. It does not document a completed BEXLIGHTING customer installation.
Catalogue options are candidates for discussion, not approved assemblies for this installation.

SR005-120P2835IP20-15M

SR005-160P2835IP20-ER90

SR005-160P2835IP20-CR80

SR005-120P2835IP20

SR005-70P2216IP20

SR005-240P2835IP20TW
BEXLIGHTING / LEARNING LIBRARY

Compare neutral-to-cool display lighting using real merchandise, neighbouring fixtures and viewing angles rather than choosing the higher Kelvin number by default.
Read the guide →
Read colour-rendering claims more carefully when selecting LED strips for timber, textiles, merchandise and interior finishes.
Read the guide →
Review the strip, profile depth, diffuser, sightline and reflective finishes together before accepting a continuous-looking cabinet light line.
Read the guide →
YOUR CABINET & FURNITURE LIGHTING
Tell us about your cabinets, wardrobes, joinery or display cases. We can discuss strip models, section lengths and connection requirements.