2835 LED Strip — ER90, 80 LEDs/m
SR005-80P2835IP20-ER90
- Voltage
- 24V
- PCB width
- 8 mm
- Protection
- IP20
BEXLIGHTING / APPLICATION DESIGN NOTE
Plinth lighting is a low-level accent, not a substitute for worktop lighting. The key decisions are source setback, floor reflection, corners, cleaning exposure and removable-panel access. Review the line from seated positions in the adjacent room as well as from the kitchen.
Show cabinet overhang, toe-kick height, setback and the planned profile. An exposed line near floor level can reflect strongly in polished tile. A matte-floor demonstration cannot predict that reflection.
| Detail | What to review |
|---|---|
| Setback | Whether the source is directly visible across the room |
| Floor finish | Reflected line, dots and local highlights |
| Corner | Permitted bend or a separate connected section |
| Appliance opening | An intentional visual break and its cable route |
| Removable plinth | Connection access without straining a lead |
There is no universal setback dimension for every cabinet and floor. Use the actual geometry and intended viewing positions.
Treat removable panels and appliance bays as service boundaries. Do not route an unreviewed continuous strip through them simply to preserve an uninterrupted visual line. Define what can be disconnected and how it is labelled.
For an L-shaped kitchen, show both legs and the corner detail. A strip's permitted bend direction and radius must come from that exact product. A flexible reel should not be assumed to tolerate a sharp fold.
Record cleaning methods, likely splashes and equipment locations. The strip body, cut ends, connectors and supply location are separate parts of the review. A body IP label does not establish the suitability of every finished connection or local installation.
Decide whether the plinth switches independently, follows a kitchen scene or responds to a sensor. Select the white appearance beside the room's other lighting. Lower-output evening use is an operating requirement; ordinary fixed-white dimming should not be described as a colour-temperature change.
Send the plinth section, floor finish, panel breaks, route drawing and control intention. The purpose is a buildable application discussion, not a claim of measured output or completed project performance.
Catalogue options are candidates for discussion, not approved assemblies for this installation.

SR005-80P2835IP20-ER90

SR005-240P2835IP20-ER90

SR005-80P2835IP20-ER80

SR005-80P2835IP20-FR90

SR005-240P2835IP20-FR90

SR005-240P2835IP20-CR80
BEXLIGHTING / LEARNING LIBRARY

A practical comparison for kitchen worktops: judge warmth, surrounding lighting, material appearance and task visibility without assuming cooler means brighter.
Read the guide →
Turn a furniture opening into an orderable strip length while allowing for marked cut intervals, end caps, connectors and service access.
Read the guide →
Define switching, dimming range and scene behaviour, then check the actual strip, driver and controller instead of matching protocol names alone.
Read the guide →
YOUR CABINET & FURNITURE LIGHTING
Tell us about your cabinets, wardrobes, joinery or display cases. We can discuss strip models, section lengths and connection requirements.