Colour-Rendering 2835 LED Strip — FR90, 25mm Cut
SR005-240P2835IP20-FR90
- Voltage
- 24V
- PCB width
- 10 mm
- Protection
- IP20

BEXLIGHTING / APPLICATION DESIGN NOTE
A vanity can need face illumination at the mirror, under-cabinet accent lighting, and separate room lighting. Define those tasks separately. An attractive glow below a floating cabinet does not establish useful light on the face or suitable equipment for the bathroom location.
External backlit-stone vanity display. This is not mirror-task lighting or a white-CCT comparison. Photo: Anna Sayapina · CC BY-SA 4.0. Resized and compressed.
Ask where light needs to reach: the face, the basin/work surface, the room or the floor below the unit. A lower concealed strip may serve the last of those well without addressing the first.
| Lighting role | Design question |
|---|---|
| Mirror task | Are the face and grooming area adequately and evenly lit? |
| Underside accent | Is the source concealed and the floor reflection acceptable? |
| Cabinet interior | Can contents be seen with drawers or doors open? |
| Room scene | How do these lights operate with the other fixtures? |
Have the responsible local professional identify the applicable equipment locations and installation requirements. Bathroom-zone definitions and protection rules vary by jurisdiction. This page should not publish one international placement rule or say that an IP number alone makes an assembly “bathroom safe”.
Include cut ends, connections, accessible supplies and the complete mounting detail in that review. Keep electrical components clear of unreviewed splash or cleaning exposure.
Use the actual basin, counter, mirror and floor materials. A glossy basin or floor can show a bright reflected line that is absent from a matte mock-up. Review the underside source at normal standing and seated views where relevant.
Check whether drawers, traps and plumbing interfere with the proposed route. A cavity behind a vanity is not automatically useful service space. Show how the cover, connector and driver are accessed without dismantling fixed plumbing or damaging joinery.
If 3000K and 4000K are being compared, judge the complete room scene and the actual finishes. Colour rendering matters when the source is part of a grooming task; a Kelvin choice alone does not establish it.
For an inquiry, provide the vanity section, intended task, finishes, reviewed location constraints, cable/service route and control behaviour. This is a coordination note, not an electrical design approval or a customer case report.
Catalogue options are candidates for discussion, not approved assemblies for this installation.

SR005-240P2835IP20-FR90

SR005-140P2216IP20

SR005-80P2835IP20-CR80

SR005-240P2835IP20-ER90

SR005-120P2835IP20-MC12V

SR005-160P2835IP20-CR80
BEXLIGHTING / LEARNING LIBRARY

Distinguish lumens, watts and useful light on the surface, then use a mounted sample to decide output for task and accent lighting.
Read the guide →
Define switching, dimming range and scene behaviour, then check the actual strip, driver and controller instead of matching protocol names alone.
Read the guide →Coordinate light position, profile fit, electrical zones and sample acceptance before cabinet drawings become a production order.
Read the guide →